Summary: An outdoor LED grille screen goes up as 1 m × 0.5 m modules on a light steel subframe — at 9–16 kg/m², each module weighs between 4.5 and 8 kg, so handling is single-person work. The critical path is not the modules: it is the subframe, the power zoning (150–600 W/m² over AC 100–240 V), and four details that decide whether the screen survives its first years — connector sealing, keeping the passive cooling path open, bonding the frame to the building's lightning protection, and designing a way to reach the screen for service. This article sets out the sequence and those details.
By INMU Technical Team · Shenzhen LEDSigns Technology Co., Ltd. (INMU) · First published: October 23, 2026
|
P15.6 |
P15.6-31 |
P25 |
P25-50 |
|
|
Module size |
1 m × 0.5 m |
1 m × 0.5 m |
1 m × 0.5 m |
1 m × 0.5 m |
|
Weight per m² |
16 kg |
11 kg |
12 kg |
9 kg |
|
Weight per module |
8 kg |
5.5 kg |
6 kg |
4.5 kg |
|
Peak power per m² |
600 W |
600 W |
500 W |
300 W |
|
Peak power per module |
300 W |
300 W |
250 W |
150 W |
|
Average power per module |
150 W |
150 W |
125 W |
75 W |
|
Permeability |
>30% |
>60% |
>53% |
>71% |
|
Brightness |
>10,000 nit |
>8,000 nit |
>6,000 nit |
>4,000 nit |
All four models: 10 mm light bars, 1R1G1B, 65,536 grayscale, 18 kHz refresh, SPI control with Nova or Cartwright cards, 80° × 80° viewing, die-cast aluminium power and control box, IP67, −40 to +50 °C, CE / RoHS / FCC.
Sealing is a cable-entry problem, not a panel problem. The module is rated IP67; the installation is only as good as its weakest gland. Every entry should face downward with a drip loop, and every connector should be seated by hand-tightened lock rather than by feel. Most wet-season failures trace back to one unsealed entry, not to a failed LED.
Do not close the cavity. These screens dissipate heat passively — no fans, no air conditioning. The open grille is the cooling path. Mounting the screen flush against a sealed wall, or boxing in the rear for neatness, traps heat and shortens life. Keep the rear ventilated.
Bond the frame. The structure is metal, mounted high, and often the tallest thing on the building. Bonding the subframe into the building's lightning protection system is a small line item on the drawing and a large claim later. INMU's products carry outdoor waterproof and lightning-protection design; the installer has to connect it.
Design the access route before fixing the first module. Front and rear service, with a module swap measured in seconds per square metre, only helps if someone can physically get there — BMU, cradle, scaffold or rope access, decided at design stage. A small stock of spare modules (typically 1–2% of the area) turns a dead pixel into an afternoon instead of a month.
Zone the power for failure, not just for load. A 100 m² P25 elevation is about 25 kW average and 50 kW peak. Isolatable zones keep one fault from taking down the whole facade during an event.
Keep one model per elevation. Mixing pitches or permeability across one continuous surface produces visible steps in brightness and openness. Where a project genuinely needs two densities, break them at an architectural line, not mid-wall.
Qingdao — 571 m² of P25-50 in a coastal climate. The installation problem was exposure: salt-laden air, sustained wind, continuous 24/7 operation. The coarse pitch kept the module count manageable, and the open structure was part of the mounting strategy rather than a by-product — permeability reduces what the subframe has to resist (see project cases).
Hainan Baisha Ecological Cultural Park — 240 m² at P50. The opposite constraint: an open landscape where the brief was integration, not impact. High permeability kept sightlines across the water and held wind load down on a structure never meant to carry a screen.
Both were installed on the same principle — the modules are the easy part; the subframe, the sealing and the access route are the project.
Q1: How much does one module weigh? Between 4.5 kg (P25-50) and 8 kg (P15.6), for a 1 m × 0.5 m module. That is single-person handling, and it is why this line installs faster than cabinet displays.
Q2: How much power does a module need? Up to about 300 W peak on the P15.6 and P15.6-31, about 250 W on the P25, and about 150 W on the P25-50. Average draw is roughly half the peak.
Q3: Does it need fans or air conditioning? No. Heat leaves through the open grille structure. The installation requirement is the opposite: keep the rear cavity ventilated.
Q4: How is it serviced? Front and rear access, with a module swap measured in seconds per square metre. The practical question is access to the screen — BMU, cradle, scaffold or rope — which must be decided before installation.
Q5: How do I plan the power distribution? Work per module and per zone. A 100 m² P25 screen is about 25 kW average and 50 kW peak; split it into isolatable zones so one fault cannot blank the whole elevation.
Q6: Can it follow a curved facade? Only in rectangular steps — the module is 1 m × 0.5 m. For curves and irregular contours, use linear fixtures or point lights; for how the rigid module behaves as a building component, see Outdoor LED Grille Screens as Rigid Building Facade Components.
About the author: This article was prepared by the INMU technical content team, Shenzhen LEDSigns Technology Co., Ltd. Founded in 2008, INMU designs and manufactures LED pixel point lights, mesh screens, grille screens, film screens, and linear video lights for architectural and urban landscape projects worldwide. Inquiries: yinmutech.com
Last updated: October 23, 2026